Test for Robot Type Extension Cable
In the following each test environment, repeat the test until the sample is electrically
disconnected, and then check the number of times.
■ Flexure test
Test environment
Sample cable
Bar
Flexure angle (R)
Weight (W)
■ Torsion test
Test environment
Rotating chuck
Drive part
Sample cable
Length (L)
Conditions
Flexure angle (θ) 180º
Weight (W)
1 kg
Length (L)
50 mm
60 times / minute
Flexure speed
• 1 round trip is done
once.
■ U bending test
Test environment
Length (L)
Moving part
Fixing part
Cable bear + Sample cable
Conditions
Length (L)
400 mm
Flexure radius (R) 18 mm
60 times / minute
Flexure speed
• 1 round trip is done
once.
Conditions
Flexure angle (θ) 90º
Weight (W)
1 kg
Flexure radius (R) 30 mm
60 times / minute
Flexure speed
• 1 round trip is done
once.
Result
≈ 32,000,000 times
Slider
Weight
(W)
Result
≈ 30,000,000 times
Flexure radius (R)
Result
≈ 42,000,000 times
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002