General Information

This product has been designed to comply with BS EN 200 for combination
taps to be used within systems designed to BS 6700.
BS 6700 recommends the temperature of stored water should never exceed
65°C. A stored water temperature of 60°C is considered sufficient to meet all
normal requirements and will minimise the build up of lime scale in hard water
areas.
If installing this product on a low pressure (tank fed) system please see
specification table below to determine the minimum distance required from
underside of the cold water tank to the outlet.
These taps and mixers should be installed in compliance with the Water
Regulations. Where the supplies are unbalanced, i.e. Hot water from cylinder
tank/cold from the mains, approved check valves must be fitted in the supply
pipes.
For further details contact your Local Water Authority.

Specifications

P r o d u c t
Code
DSC 3HBAS C
DSC 3HBF C
DSC WMBAS
C
DSC WMBF C
DSC BS C
Maximum static pressure: 10.0 bar
System Requirements:
Gravity fed hot & cold (Equal pressures)
Gravity fed hot & cold (Differential pressure, maximum ratio 5:1)
Unvented systems
Instantaneous water heater (Combination boiler)
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
4
Working
Pressures
Min
Max
0.2
5.0
15mm Compression
Threaded Tail
0.4
5.0
3/4" BSP Threaded Tail
0.2
5.0
15mm Compression
Threaded Tail
0.5
5.0
22mm Compression
Threaded Tail
0.2
5.0
1/2" BSP Threaded Tail
Minimum distance
from cold water
Inlet
tank to outlet
(metres)
2
4
2
5
2