Major tech SL93 Petunjuk - Halaman 2

Jelajahi secara online atau unduh pdf Petunjuk untuk Lampu Banjir Major tech SL93. Major tech SL93 3 halaman. Passive infrared light

I.
Avoid installing the unit in direct sunshine
zones or where air stream and temperature
have
obvious
alteration,
according to the right fig.
N – blue (Neutral)
L – brown (Live)
Ⅱ . 1 Please shut off the power before installation.
(See following diagram)
2 please tighten off the screw on the rear lid of
junction box.
3 Please connect the power into sensor lamp according to connection figure.
4 Please install the sensor lamp on the selected position according to installation diagram.
5 please cover the rear lid and tighten the screw. Then you can test it after electrifying.
Test:
1) Sensitivity: Adjust the knob "1" clockwise to raise its sensitivity and anti-clockwise to reduce
its sensitivity.
2) Adjust the knob" 2"
3) Light control: Adjust the knob" 3" to select different working ambient-light.(See Fig.)
4) Switch on the power, the lamp will turn on within 5s and go out within 5~30s;after 10s it will
be on again
5) Turn the light-control to night, cover the detection window with the opaque object, the lamp
should be on, then go out after 5~10s.
6) If the function above-mentioned is normal, you can set the light-control, sensitivity and
time-delay according to your demand, then electrify to use it.
Note:
Avoid install it where there is sunshine or air stream and temperature change obviously,
Avoid touching the lens device with sharp things and coarse
pollutant.
MAJOR TECH (PTY LTD
Head Office:
Cnr Rover & Jaguar Roads, Rustivia Ext 3,
connect
line
brown(L)
blue(N)
clockwise to last operating time and anti-clockwise to shorten it .
~input
infrared motion sensor
load
1
2
3
output red(A)