Ganz C-AllView Panduan Pemasang - Halaman 12
Jelajahi secara online atau unduh pdf Panduan Pemasang untuk Kamera Keamanan Ganz C-AllView. Ganz C-AllView 20 halaman.
Fuses
Mains input
Power input (F0)
Power PTZ output (F1)
Washer pump (F2)
Connecting the composite cable
1 Open one of the knock-out panels of the wiring centre box and fit a suitable
cable water-sealing cable grommet.
2 Feed the bare ends of the composite cable in through the grommet and connect
each cable within the wiring centre as follows:
• Primary video
Fit a BNC connector to coaxial cable marked as 'Video 1' and connect it to the
BNC socket labelled 'VIDEO IN 1'.
• Secondary video (if present)
Fit a BNC connector to coaxial cable marked as 'Video 2' and connect it to the
BNC socket labelled 'VIDEO IN 2'.
• Power
Connect the Red cable to the terminal marked 'PTZ 1P'.
Connect the Black cable to the terminal marked 'PTZ 1N'.
• Washer
Connect the Orange cable to the upper terminal marked 'AUX1'.
Connect the White cable to the upper terminal marked 'AUX2'.
• RS485 telemetry
Connect the Yellow cable to the upper terminal marked 'DATA 5'. Connect
the Blue cable to the upper terminal marked 'DATA 6'.
• Earth
Connect the Green/Yellow cable to the Earth connection of the mains input
terminal block.
The IR Lamp and Ethernet terminals are reserved for future use.
0
RC-PSB1
230VAC
3.15A
24VAC
3.15A
24VAC
2A
24VAC
1A
RC-PSB2
3.15A
5A
2A
2A