INSTALLATION INSTRUCTIONS
m?scscc ton
It is recommended
that the vent system be installed before
7. Tape template in place, aligning the template centerline and
hood is installed,
bottom of template with hood bottom line and with the
centerline marked on the wall.
Do not cut a joist or stud unless absolutely necessary. If a
joist or stud must be cut, then a supporting
frame must be
i
A
constructed.
_==
....
•
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
•
Check your ceiling height and the hood height maximum
before you select your hood.
Excessive
Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
1. If possible, disconnect
and move freestanding
or slide-in
range from cabinet opening to provide easier access to rear
wall. Otherwise, put a thick, protective covering over
countertop,
cooktop or range to protect from damage or dirt.
2. Determine which venting method to use: roof, wall, or non-
vented.
3. Select a flat surface for assembling the range hood. Cover
that surface with a protective covering.
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
4=
5.
6.
Using 2 or more people, lift range hood onto protective
covering.
Determine and mark the centerline on the wall where the
canopy hood will be installed.
Select a mounting height between a minimum of
30" (76.2 cm) and a suggested maximum of 36" (91.4 cm),
above the range to the bottom of the hood and mark
reference line on the wall.
NOTE: For installation locations with reduced ceilings
heights, the vent hood may be installed using the upper vent
cover for both vented and non-vented
(recirculating)
installations.
8=
#
<
=
0
0
0
0
jJ
g
s f
0
..............................
0
C
b,
3 =
D
A. Centerline
B. Mounting hook location
C. Fastener locations
D. Mounting height reference
Mark centers of the 6 fastener locations through the template
to the wall.
IMPORTANT: All screws must be installed into wood.
Remove the template.
9. Drill %4" (2.75 mm) pilot holes at all locations where screws
are being installed into wood.
10. Determine and make all necessary cuts in the wall for the vent
system. Install the vent system before installing the hood. See
"Venting Requirements"
section.
11. Determine the required height for the 1/2"conduit and drill a
11¼"(3.2 cm) hole at this location.
12. Run wire through the 1/2"conduit according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough 1/2"conduit and wires from
the fused disconnect
(or circuit breaker) box to make the
connection
in the hood's electrical terminal box.
13. Use caulk to seal all openings.
NOTE: Do not reconnect power until installation is complete.