IKEA IUD8500BX1 Panduan Petunjuk Instalasi - Halaman 21
Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Mesin pencuci piring IKEA IUD8500BX1. IKEA IUD8500BX1 26 halaman.
Drain hose
Drain hose stop
Stop
Using pliers, squeeze open the small drain hose clamp and slide
onto connector between stops.
Drain hose
Rubber drain hose
connector
Small clamp
After hose is connected, remove towel.
NOTE: If the power supply cord was connected earlier, proceed to
"Secure Dishwasher in Cabinet Opening" section.
Option B, Direct Wire:
Route cable so that it does not touch dishwasher motor or lower
part of dishwasher tub. Pull cable through UL Listed/CSA
Approved strain relief in terminal box. Strain relief is not supplied
with the dishwasher. Owner must purchase a 7/8"screw-in type
strain relief.
Select UL Listed/CSA Approved twist-on wire connectors
(not
included) rated to connect your household wiring to 16-gauge
dishwasher wiring.
Electrical
Shock Hazard
Electrically
ground dishwasher.
Connect ground wire to green ground connector in
terminal
box.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
Form bare ground wire into a U-shaped hook. Wrap ground wire
hook clockwise around ground connector screw and under the
washer. Securely tighten ground connector screw.
NOTE: Do not pre-twist stranded wire. Twist on UL listed/CSA
approved wire connector. Gently tug on wires to be sure both are
secured.
21