Avantco 178GDICE49FB Panduan Servis - Halaman 4

Jelajahi secara online atau unduh pdf Panduan Servis untuk Penata barang dagangan Avantco 178GDICE49FB. Avantco 178GDICE49FB 18 halaman. Ice merchandisers

Avantco 178GDICE49FB Panduan Servis
Troubleshooting
(Continued)
Problem
Compressor is not running
Unit turns off before
reaching set temperature
Inside cabinet fan not
working
Water is coming from
under the unit
E0 error showing on
controller
E1 error showing on
controller
www.AvantcoRefrigeration.com
4
Service Manual
Ice Merchandisers
Ensure unit is plugged in and turned on
Ensure controller parameters are correct
Check controller is telling compressor to run
Check start components
Check compressor for power
Ensure proper voltage on the plug
Ensure controller settings are correct
Ensure condenser coil is clean
Ensure controller is sending power to compressor
Check cabinet temperature sensor
Check compressor for power
Check parameters are correct on controller
Check controller is telling evaporator fan to run
Check door switch
Check evaporator fan motor
Check drain hose is inside condensate pan
Check parameters are correct on controller
Check defrost element
Check drain hose for clogs
Ensure wiring into controller is secure
Check cabinet temperature sensor
Ensure wiring into controller is secure
Check evaporator temperature sensor
Possible Solution