CORNING EDC-02P-NH Manual - Halaman 7

Jelajahi secara online atau unduh pdf Manual untuk Kandang CORNING EDC-02P-NH. CORNING EDC-02P-NH 7 halaman. Environmental distribution center
Juga untuk CORNING EDC-02P-NH: Manual (12 halaman)

CORNING EDC-02P-NH Manual
10.
INSTALLING DROP CABLE
Step 1:
Cut subunit lengths to 51 in (130 cm).
Step 2:
Feed cable through fitting in base.
Step 3:
If no central member is present, loosely secure cable to the drop cable strain-relief bracket
with a cable tie. If there is a central member present, remove the bracket and strain-relieve
as decribed in Section 7.
Step 4:
route the cable through the radius guides/routing clips.
Step 5:
Clean and mate the connectors and adapters.
EDC-02P-NH
11.
FINALIZE INSTALLATION
Step 1:
Record fiber identification on the label in
a logical way and attach to inside of front door.
Step 2:
Secure front door with slotted screwdriver.
NOTE:
the optional Quick release Latch Kit may be installed
to facilitate access to the housing. A padlock may be
installed to prevent unauthorized access.
Corning Cable Systems LLC • PO Box 489 • Hickory, NC 28603-0489 USA
1-800-743-2671 • FAX +1-828-325-5060 • International +1-828-901-5000 • http://www.corning.com/cablesystems
Corning Cable Systems reserves the right to improve, enhance, and modify the features and specifications of Corning Cable Systems' products without prior notification. All
trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified.
© 1999, 2000, 2004, 2010 Corning Cable Systems. All rights reserved. published in the USA.
STANDARD RECOMMENDED PROCEDURE 003-304 | ISSUE 10 | September 2010 | PAGE 7 OF 7