Juga untuk Jandy Jandy Pro Series: Panduan Pemilik (12 halaman), Panduan Instalasi (16 halaman), Panduan Pemilik (20 halaman), Manual (8 halaman), Panduan Memulai Cepat (2 halaman), Panduan Instalasi dan Pengoperasian (20 halaman), Petunjuk Instalasi (2 halaman), Panduan Instalasi dan Pengoperasian (16 halaman), Panduan Instalasi dan Pengoperasian (16 halaman), Panduan Instalasi dan Pengoperasian (16 halaman)

Jandy Jandy Pro Series Panduan Instalasi dan Pengoperasian
Page 10
ENGLISH
6. Connect the other end of the cable to an RS-485
connector on the AquaLink RS (or multiplexer
interface board), matching wire colors with
connector positions See "Figure 5. Wiring
AquaLink RS, PDA or Z4"
7. Restore power to the pump and verify the
operation of the controller.
8. Refer to the appropriate manual for set up and
operation of the pump:
• AquaLink RS Manual #6593
• AquaLink PDA Manual #H0572300
• AquaLink Z4 Manual #H0386600.
Connect to AquaLink RS RS-485 Connector
(or Multiplexer Interface Board)
S1
S2
4-Position
DIP Switch
Figure 5. Wiring AquaLink RS, PDA or Z4
3.2.4.2 Install with JEP-R variable-speed
controller
IMPORTANT
The installer must TURN ON switches 1 and 2 at the
VS-FHP2.0 pump when connected to the variable-
speed controller.
1. Disconnect the high voltage lines or open any
breaker to which the pump power is connected.
Jandy
Pro Series VS PlusHP Pumps
®
4 3 2 1
4 3 2 1
6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
RS6 & RS8 ONLY
RS8 ONLY
RESET
POOL MODE
SPA MODE
AUTO
SPA DRAIN
SERVICE
HEATER
SOLAR
SPA FILL
TIME OUT
4 3 2 1
4 3 2 1
Variable-Speed
Pump
|
Installation & Operation Manual
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in
the variable-speed pump electrical circuit before
starting the procedure. Failure to comply may
cause a shock hazard resulting in severe personal
injury or death.
2. Remove the junction box cover and feed the
RS-485 cable into the fi tting.
3. Unplug the RS-485 connector.
4. Attach the four (4) RS-485 cable wires to the
RS-485 connector. Match the wire colors with the
positions on the connector: See "Figure 6. Wiring
JEP-R VSP Controller"
5. Insert the RS-485 connector back into the junction
box.
6. Dip switches 1 and 2 must be in the ON position,
and switches 3 and 4 must be in the OFF position.
See "Figure 6. Wiring JEP-R VSP Controller"
4-Position
DIP Switch
Figure 6. Wiring JEP-R VSP Controller
7. Connect the other end of the cable to the
controller. Match the colors of the wires with the
appropriate connector positions. See "Figure 6.
Wiring JEP-R VSP Controller"
8. Restore power and verify the operation of the
controller.
9. Refer to the Variable-Speed Controller Owner's
Manual, H0412200, to operate the pump.
Controller
(Rear View)
5 4 3 2 1
4 3 2 1
RS485
REMOTE CONTROL
4 3 2 1
Variable-Speed
Pump