Juga untuk Jandy Jandy Pro Series: Panduan Pemilik (12 halaman), Panduan Instalasi (16 halaman), Panduan Pemilik (20 halaman), Manual (8 halaman), Panduan Memulai Cepat (2 halaman), Panduan Instalasi dan Pengoperasian (20 halaman), Petunjuk Instalasi (2 halaman), Panduan Instalasi dan Pengoperasian (16 halaman), Panduan Instalasi dan Pengoperasian (16 halaman), Panduan Instalasi dan Pengoperasian (16 halaman)

Jandy Jandy Pro Series Panduan Instalasi dan Pengoperasian
Page 12
ENGLISH
3.2.6.2 Contact Opening
If the pump speed is below 1725 RPM, the Auxiliary
Load contact is opened. Contact openings are always
immediate.
Section 4.

Operation

4.1

Remove Pump Lid

1. Make sure that the pump is turned off.
2. Make sure that the switch to the circuit breaker
that powers the pump motor is turned off.
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in
the variable-speed pump electrical circuit before
starting the procedure. Failure to comply may
cause a shock hazard resulting in severe personal
injury or death.
Figure 9. Disengage Lock Ring
Jandy
Pro Series VS PlusHP Pumps
®
Rotate locking ring
counter clockwise
Align START
with port
|
Installation & Operation Manual
Figure 10. Remove Pump Lid
ELECTRICAL SHOCK HAZARD
Due to the potential risk of fire, electric shock, or injuries
to persons, Zodiac
Pumps and any auxiliary loads must
®
be installed in accordance with the National Electrical
Code
(NEC
), all local electrical and safety codes, and
®
®
the occupational Safety and Health Act (OSHA). Copies
of the NEC may be ordered from the National Protection
Association, 470 Atlantic Ave., Boston, MA 02210, or
from your local government inspection agency.
In Canada, Zodiac Pumps must be installed in
accordance with the Canadian Electrical Code (CEC).
3. Make sure all necessary isolation valves are closed
to prevent pool water from reaching the pump. If
the pump is installed below water level, ensure all
necessary isolation valves are closed to prevent
pool water from reaching the pump.
4. Turn the locking ring counter-clockwise until
the 'START' markings align with the ports. See
Figure "Figure 9. Disengage Lock Ring"
5. Carefully lift to remove the lid with locking ring.
Locking Ring
Lid
Seal
Basket
WARNING