It is not necessary to remove the work-
top when installing under a standard
kitchen counter. Only remove the work-
top when installing the appliance under a
close fitting sink unit or kitchen counter
(820 mm).
Put the appliance adjacent to a water tap
and a water drain.
Make sure that the dimensions of the
recess agree with the dimensions in the
picture.
min 570 mm
820 mm
600 mm
Removing the work-top
1. Remove the rear screws (1).
1
2. Pull the work-top from behind (2).
3. Lift the work-top and move it from
the front slots (3/4).
3
2
4
4. Level the appliance using the
adjustable feet.
5. Install the appliance under the
kitchen counter.
Adjusting the level of the
appliance
A correct adjustment of the level of the
appliance allows the door to close and
seal correctly.
If the door does not close correctly,
loosen or tighten the adjustable feet to
level the appliance.
14.2 Water connection
Water inlet hose
Connect the inlet hose to a water tap
with an external BSP thread spout of
3/4''.
For best washing performance it is
recommended to connect the appliance
to a cold water supply.
Energy savings can be made by
connecting the appliance to a Solar
water system and using economy
options, however the water temperature
must not exceed 60° C.
Inlet water supply
• Water pressure: 800 kPa max - 50 kPa
min.
• Water flow rate 10 L / minute min.
• If water pressure is in excess of 800
kPa, a pressure reducing valve should
be used. Check for leaks.
• If water temperature is in excess of
60° C, a tempering valve should be
used. Check for leaks.
CAUTION!
Always use new hoses when
you connect the appliance
to the water mains. Old
hoses must not be used. The
water inlet hose must be
examined at an interval of
twelve months for
deterioration and replaced if
necessary.
The water pressure must be in the limits
indicated in the chapter ''TECHNICAL
ENGLISH
21