Adaptation to different types of gas

Injectors replacement
Remove the pan supports.
Remove the burner's caps and crowns.
With a socket spanner 7 unscrew and remove
the injectors (Fig. 6), and replace them with
the ones required for the type of gas in use.
Reassemble the parts, following the same
procedure backwards.
Replace the rating label (placed near the
gas supply pipe) with the relevant one for the
new type of gas supply. You can find this
label in the package of the injectors supplied
with the appliance.
Should the feeding gas pressure be different or
variable compared with the required pressure,
an appropriate pressure adjuster must be fitted
on the gas supply pipe, in compliance with the
rules in force.
Adjustment of minimum
level
To adjust the minimum level of the burners,
proceed as follows:
Light the burner.
Turn the knob on the minimum position.
Remove the knob.
With a thin screwdriver, adjust the by-pass screw
(fig. 7). If changing from natural gas to LPG,
completely tighten clockwise the screw, until a
small regular flame is obtained.
Finally check the flame does not go out when
quickly turning the knob from the maximum position
to the minimum position.
This procedure can easily be carried out, anyhow the hob
has been positioned or built in the working top.
FO 0392
By-pass screw
By-pass diameters
Burner
Auxiliary
Semi-rapid
Rapid
Fig. 6
Fig. 7
Ø By-pass
in 1/100
of mm.
28
32
40
47