Installation

! Please keep this instruction booklet in a safe place
for future reference.. Make sure the booklet remains
with the appliance if it is sold, given away or moved.
! Please read this manual carefully: it contains
important information on installation, operation and
safety.
! The appliance must be installed by a qualified
professional in accordance with the instructions
provided.
! Any necessary adjustment or maintenance must be
performed after the cooker has been disconnected
from the electricity supply.

Positioning and levelling

! The appliance may be installed alongside any
cupboards whose height does not exceed that of the
hob surface.
! Make sure that the wall which is in contact with the
back of the appliance is made from a non-
flammable, heat-resistant material (T 90°C).
To install the appliance correctly:
• Place it in the kitchen, the dining room or the
studio flat (not in the bathroom).
• If the top of the hob is higher than the cupboards,
the appliance must be installed at least 600 mm
away from them.
• If the cooker is installed underneath a wall cabinet,
there must be a minimum distance of 420 mm
between this cabinet and the top of the hob.
HOOD
600
Min.
mm.
• Any hoods must be installed in accordance with
the instructions listed in the relevant operating
manual.
This distance should
be increased to 700
mm if the wall cabinets
are flammable ( see
figure ).
• Do not position
blinds behind the
cooker or less than 200
mm away from its
sides.
Levelling
If it is necessary to level the
appliance, screw the
adjustable feet into the
positions provided on each
corner of the base of the
cooker ( see figure ).
The legs* fit into the slots on
the underside of the base of
the cooker.

Electrical connection

Fitting the power supply cable
To open the terminal board:
• Insert a screwdriver into the side tabs of the
terminal board cover.
To install the cable, follow the instructions below:
• Loosen the cable clamp screw and the wire
contact screws.
! The jumpers are pre-set at the Factory for 230 V
single-phase connection ( see figure ).
230V ~
H05RR-F 3x4 CEI-UNEL 35363
N
• To carry out the electrical connections as shown in
the figures, use the two jumpers inside the box
( see figure - labelled "P").
• Pull the cover to
open it.
L
13