CHILLER INSTALLATION
Install the wall hanger onto the wall according to the rough in drawing. The Wall hanger is
shipped fastened to the back of the chiller unit.
Once the chiller unit is hung on the wall, Install a p trap in the waste line and a shut off valve in
water supply line.
An in line strainer is furnished in "Water Supply" tube. Connect "Water Supply" tube to shut off
valve. NOTE: This connection should not be a solder joint or flare connection to allow access
to the strainer for service. Using one of the 1 3/4" diameter knockouts for a waste line is not
recommended because of a potential conflict with ADA toe space clearance requirements.
Check your local building code inspector for approval.
Rotate fan blade by hand to see that it is free of obstructions.
Leave the front panel off for the Bottle Filler installation.
Your Partner in Cool.
6
BOTTLE FILLER INSTALLATION
The PN8EBFY comes partially assembled for shipping. Remove the kit from the packaging and
separate it into the assemblies and components shown below.
Tool Needed: T15 Torx bit
Place the bottle filler frame against the wall and set it onto the top flange of the chiller frame.
7