Aqua Logic ALCUV-2 Panduan Petunjuk Pemasangan & Pengoperasian - Halaman 6

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pemasangan & Pengoperasian untuk Peralatan Laboratorium Aqua Logic ALCUV-2. Aqua Logic ALCUV-2 9 halaman. Compact uv

Other Maintenance:

Replace the Ballast:
Unplug UV sterilizer from outlet.
Remove screws from UV lid and front cover,
remove the both covers.
Place new ballast near UV.
Remove screws which hold ballast to unit.
Remove old ballast.
Mount new ballast with screws.
Strip approximate ¾-inch insulation from ends of
red and blue wires on ballast and on bulb
connector assemblies.
Replace UV sterilizer lid and front cover. Install
screws.
Apply power to UV sterilizer.
The view port should show a blue light after a few seconds.
©2004 Aqua Logic,® Inc. 8268 Clairemont Mesa Blvd. Suite 302 San Diego, CA. 92111
Ph (858) 292- 4773 FAX (858) 279-0537 email: [email protected] website: www.aqualogicinc.com
Page 6