Aqua Logic ALCUV-2 Instrukcja instalacji i obsługi - Strona 6
Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Sprzęt laboratoryjny Aqua Logic ALCUV-2. Aqua Logic ALCUV-2 9 stron. Compact uv
Other Maintenance:
Replace the Ballast:
•
Unplug UV sterilizer from outlet.
•
Remove screws from UV lid and front cover,
remove the both covers.
•
Place new ballast near UV.
•
Remove screws which hold ballast to unit.
•
Remove old ballast.
•
Mount new ballast with screws.
•
Strip approximate ¾-inch insulation from ends of
red and blue wires on ballast and on bulb
connector assemblies.
•
Replace UV sterilizer lid and front cover. Install
screws.
•
Apply power to UV sterilizer.
•
The view port should show a blue light after a few seconds.
©2004 Aqua Logic,® Inc. 8268 Clairemont Mesa Blvd. Suite 302 San Diego, CA. 92111
Ph (858) 292- 4773 FAX (858) 279-0537 email: [email protected] website: www.aqualogicinc.com
Page 6