REASSEMBLY PROCEDURES

1.
Place a new, lubricated o-ring (11) onto the crown orifice
(12). Load the crown orifice onto the installation / extraction
tool flat end first.
2.
Insert the crown orifice (12) into the inlet side (non-threaded
side) of the body (8). Turn the tool over and press on the
head of the crown orifice to confirm that it is seated all the
way in the body.
3.
Install a new, lubricated o-ring (5) into its groove on the
piston (4) shaft.
4.
Install a new, lubricated o-ring (3) onto the head of the
piston (4).
5.
Using your finger, press a new HP (6) seat into the end of
the piston (4) until it is seated all the way and is flush with
the end of the piston. If you are unable to press the HP seat
into the piston all the way with your finger, as an option, you
can place the HP seat on a clean surface and press the
piston shaft over it.
6.
Apply a coat of Christo-Lube to the outside of the piston
head o-ring (3). Insert the piston (4), head first, into the cap
(2).
7.
Apply a coat of Christo-Lube to the outside of the shaft
o-ring (5). Lower main spring (7) over the shaft of the piston
(4).
8.
Apply a light coat of Christo-Lube to the threads on the
main body (8). Mate the cap assembly (2) to the main body.
Thread until hand-tight.