9.
Install a new, unlubricated o-ring (15) into the groove inside
the inlet fitting (17).
10.
Install a new, lubricated o-ring (16) onto the outside of the
inlet fitting (17). Using your finger, press fit a new conical
filter (14), narrow end first, into the inlet fitting.
NOTE:
Be carefull not to get any lubricant on or near the
conical filter.
11.
Load the body (8) into a
vise using the vise-mount-
ing tool. Using a large
crescent wrench, snug the
cap (2) onto the body mak-
ing sure that metal meets
metal.
12.
Invert the body (8) in vise. Install the cosmetic black washer
(13), smooth side up, onto the body. Set the yoke (18) on
top of the washer.
13.
Thread in the inlet fitting
(17). Using a ft/lbs torque
wrench, the 111001 modi-
fied 26mm socket and a 3"
extension, apply a torque of
18 ft/lbs to the inlet fitting.
Install dust cap (19) and
yoke screw (22).
14.
Install o-rings (9,21) on to each port plug (10,20). Using a
4mm allen key, install each of the port plugs into its respec-
tive port.
15.
Install the interstage hose into its respective port. Using
an in/lbs torque wrench and a 9/16" crows foot, torque the
hose to 40 in/lbs.
16.
Slide hose protector back
into position.
7