Billi Quadra Panduan Pengguna - Halaman 10
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Produk Pipa Billi Quadra. Billi Quadra 13 halaman. Xl, xt, xr tap options
Juga untuk Billi Quadra: Panduan Instalasi (8 halaman), Panduan Pengguna (12 halaman), Panduan Instalasi (7 halaman)

- 1. Warnings & Important Information
- 1. Warnings & Important Information
- 2. General Maintenance
- 2. General Maintenance
- 3. Features and Modes
- 3. Features and Modes
- 4. Options and Operation
- 4. Options and Operation
- 5. Safety Switch Settings
- 5. Safety Switch Settings
- 6. Dispenser Icon Codes
- 6. Dispenser Icon Codes
- 7. Dispenser Icon
- 7. Dispenser Icon
- 8. Filter Change Due Monitor
- 8. Filter Change Due Monitor
User guide
Billi Quadra & Quadra Sparkling Plus – XL.
Installing the CO
1 . Ensure all connections between the
regulator and unit are secure .
Position the regulator on top of the CO
cylinder .
2 . Tighten the bottle by rotating anti-clockwise .
– CO
will escape while you are turning the
2
bottle . Continue to turn the bottle to form
a seal with the regulator .
3 . Open the pressure regulator by turning the
black knob clockwise .
– Set the initial pressure to around 3 Bar .
– Turn on the unit power and water supply .
– Wait for the unit to come back to
temperature .
4 . Check bottle and connections for leaks using
soapy water to test for bubbles .
NOTE: the ¼" tube and pushfit fittings may
settle when the pressure is turned on .
5 . Increase the pressure to set your level of
carbonation .
Initial set point may vary once the unit is
running, you may need to reset the pressure
once the system has stabilised .
WARNING: do not set the pressure above 5 bar .
10
cylinder
2
2