Billi Quadra 4100 Panduan Instalasi - Halaman 3

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Perlengkapan Dapur & Kamar Mandi Billi Quadra 4100. Billi Quadra 4100 12 halaman. Tower dispenser
Juga untuk Billi Quadra 4100: Panduan Instalasi (8 halaman)

Billi Quadra 4100 Panduan Instalasi
Installation guide
Billi Quadra – Firewall Tower
Installation Requirements – Quadra
Components for Billi Quadra Compact, 420, 440, 460, 4100 & 4180 Models
Before commencing installation, ensure you have the following:
1. Underbench module
2. Dispenser with tubing
3. Tube spring clamps x 3
4. 600mm flexible braided hose
5. ½ inch drill bit (not included)
6. Drain fittings including John Guest fittings
7. 3/8 tube connected with adapter to 3/16 black tube
8. Filter Cartridge (installed)
9. User guide
10. Warranty Registration Card
11. Warning label
Determine Unit Location
Plan the installation. Dispenser tube lengths, position of power and water outlets, required air space
around the under bench module and access for service must be considered before cutting tube lengths.
Refer to Diagrams 3 and 4 for clearances around the dispenser and unit.
Unit must be installed horizontally with plastic vent panel facing the front of cupboard. The Quadra is
designed for internal installation only.
Model
Quadra Compact
Quadra 400 Models
Water Supply
The Quadra must only be connected to a cold water supply. A ½" BSP stop tap (not supplied) is to be
installed in an easily accessible position within 600mm from the Quadra water supply inlet. The Quadra
incorporates a certified pressure limiting and backflow prevention device. Do not fit an additional
pressure limiting valve.
Dynamic inlet supply pressure: Min. 250 kPa, max. 500 kPa*
Supply Temperature: min. 5°C max. 30°C.
*Where supply pressure is greater then 500kPa a PLV must be fitted. Billi recommends PLVs with anti-
hammer properties.
Do not install with water that is microbiologically unsafe or with water of unknown quality
without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected water that may contain
filterable cysts.
Power Requirements
3 pin GPO
required. A dedicated circuit should be provided and must be fitted with an earth
leakage protection device (RCD). An externally fitted RCD device is acceptable.
Quadra Compact, 420, 440, and 460 require a 10 amp rating.
Quadra 4100 requires a 15 amp rating.
Quadra 4180 requires a 20 amp rating.
All Quadra models are supplied with a 1 metre flex cord and plug.
Height
340mm
340mm
Width
Depth
315mm
365mm
315mm
465mm
3