Dell PowerEdge 1655MC Panduan Tambahan - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Tambahan untuk Server Dell PowerEdge 1655MC. Dell PowerEdge 1655MC 24 halaman. Removing a fan
Juga untuk Dell PowerEdge 1655MC: Manual Perangkat Keras (10 halaman), Manual Perangkat Keras (14 halaman)

Dell PowerEdge 1655MC Panduan Tambahan
The following is an example of the display if two drives are installed in mirrored mode:
HBA
ID
LUN
VENDOR PRODUCT
0
0
0
Dell VIRTUAL DISK
0
7
0
LSI Logic 1020/1030
Table 1-1 lists the possible messages displayed for mirrored mode and the actions
required.
Ta b l e 1 - 1 .
Message
Logical drive optimal
Logical drive
resynchronizing
Logical drive degraded

Manually Deconfiguring Mirrored Mode

Press <Ctrl><Alt><Delete> to reboot the server module.
1
The following message is displayed during POST:
Press CTRL-M to start LSI logic configuration utility
Press <Ctrl><M> or <Esc><Ctrl><M> to access the LSI utility.
2
Press <Enter> to access the Adapter Properties Menu.
3
1-4
Repl aci ng the S er v er Mo dule Bo ard
M i r r o r e d M o d e M e s s a g e s a n d A c t i o n s
Action
Go to "Replacing the Server Module Board."
Go to "Manually Deconfiguring Mirrored Mode."
NOTICE: If this message is displayed, press
<Ctrl><Alt><Delete> immediately before the server module
boots to the operating system.
A hard drive is faulty. See "Troubleshooting Hard Drives" in your
Installation and Troubleshooting Guide.
NOTE: If you are using console redirection, you must press <Esc><Ctrl><M>.
REV
SYNC
1000
1000c00
320.0
WIDE
CAPACITY
16
18203 MB
16