Dell PowerEdge 1655MC Manuale supplementare - Pagina 8

Sfoglia online o scarica il pdf Manuale supplementare per Server Dell PowerEdge 1655MC. Dell PowerEdge 1655MC 24. Removing a fan
Anche per Dell PowerEdge 1655MC: Manuale hardware (10 pagine), Manuale hardware (14 pagine)

Dell PowerEdge 1655MC Manuale supplementare
The following is an example of the display if two drives are installed in mirrored mode:
HBA
ID
LUN
VENDOR PRODUCT
0
0
0
Dell VIRTUAL DISK
0
7
0
LSI Logic 1020/1030
Table 1-1 lists the possible messages displayed for mirrored mode and the actions
required.
Ta b l e 1 - 1 .
Message
Logical drive optimal
Logical drive
resynchronizing
Logical drive degraded

Manually Deconfiguring Mirrored Mode

Press <Ctrl><Alt><Delete> to reboot the server module.
1
The following message is displayed during POST:
Press CTRL-M to start LSI logic configuration utility
Press <Ctrl><M> or <Esc><Ctrl><M> to access the LSI utility.
2
Press <Enter> to access the Adapter Properties Menu.
3
1-4
Repl aci ng the S er v er Mo dule Bo ard
M i r r o r e d M o d e M e s s a g e s a n d A c t i o n s
Action
Go to "Replacing the Server Module Board."
Go to "Manually Deconfiguring Mirrored Mode."
NOTICE: If this message is displayed, press
<Ctrl><Alt><Delete> immediately before the server module
boots to the operating system.
A hard drive is faulty. See "Troubleshooting Hard Drives" in your
Installation and Troubleshooting Guide.
NOTE: If you are using console redirection, you must press <Esc><Ctrl><M>.
REV
SYNC
1000
1000c00
320.0
WIDE
CAPACITY
16
18203 MB
16