Microprocessor Upgrade Installation Guide
,QVWDOOLQJ DQ 8SJUDGH 0LFURSURFHVVRU LQ
3RZHU(GJH 6\VWHPV
This section provides instructions for:
‡
Removing the cooling shroud, single-edge contact (SEC) cartridge, and heat sink
‡
Installing the new SEC cartridge and heat sink and replacing the cooling shroud
‡
Reassembling and checking the system
5HPRYLQJ WKH &RROLQJ 6KURXG 6(& &DUWULGJH DQG
+HDW 6LQN
1.
Turn off the system, including any attached peripherals, and disconnect the power
cable from the electrical outlet.
2.
Remove the right-side system cover and bezel.
See your system Installation and Troubleshooting Guide for specific instructions,
if needed.
3.
Remove the cooling shroud as follows:
a.
Unscrew and remove the two retention pins (see Figure 1-1).
b.
Remove the shroud by lifting the end of the shroud closest to the micropro-
cessor(s) until the opposite end of the shroud disengages from the cooling
fan on the system's back panel (see Figure 1-1).