Dell PowerEdge 2450 Panduan Instalasi - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Server Dell PowerEdge 2450. Dell PowerEdge 2450 20 halaman. Wake-on-lan (wol) support on dell servers
Juga untuk Dell PowerEdge 2450: Panduan Instalasi (26 halaman), Instal Manual (32 halaman), Pembaruan Informasi (12 halaman), Panduan Tambahan (30 halaman), Panduan Pemasangan Perangkat Keras (32 halaman), Manual Perangkat Lunak (10 halaman), Panduan Instalasi (8 halaman), Manual (15 halaman)

Dell PowerEdge 2450 Panduan Instalasi
(Rev. 11/3/98) FILE LOCATION: S:\SYSTEMS\SlimFast\ts\ProcUpgrade\028WD\028wdeb0.fm
support.dell.com
thumbscrew
retention pins (2)
)LJXUH 5HPRYLQJ WKH &RROLQJ 6KURXG )URP WKH 3RZHU(GJH
4.
Remove the SEC cartridge and heat sink as follows.
a.
Pull the tab on one side of the guide-bracket assembly away from the end of
the heat sink and pull up slightly on the SEC cartridge and heat sink (see
Figure 1-2).
b.
Pull the tab on the other end of the guide-bracket assembly to disengage the
tab on the heat sink, and then lift the SEC cartridge and heat sink away from
the guide-bracket assembly (see Figure 1-2).
DELL CONFIDENTIAL - Preliminary
9/11/00
Microprocessor Upgrade Installation Guide
1-5