Dell PowerEdge C6105 Gunakan Manual - Halaman 46

Jelajahi secara online atau unduh pdf Gunakan Manual untuk Server Dell PowerEdge C6105. Dell PowerEdge C6105 46 halaman. Rack server
Juga untuk Dell PowerEdge C6105: Panduan Portofolio (27 halaman), Panduan Teknis (36 halaman)

Dell PowerEdge C6105 Gunakan Manual
>11 00 00
2 Enable and Set VLAN ID :
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x0C
0x01 0x01 0x14 0x02 0x80
3 Disable VLAN ID :
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x0C
0x01 0x01 0x14 0x00 0x00
BMC Version Information
The BMC firmware version can be obtained by using the IPMI - Get Device
ID command.
To get the BMC firmware version:
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x06
0x01
>20 01 01 16 02 bf 4c 1c 00 47 32 11 76 00 00 Version 1.16
BIOS Firmware Information
The BIOS firmware version can be obtained by using the IPMI - Get Device
ID command.
To get the BIOS firmware version:
> ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x30
0x1e
> 53 32 47 5F 33 41 31 35 00 00 Present with ASCII Code : S2G_3A15
46
VLAN is disabled/VLAN ID is zero.