Dell PowerEdge C6105 매뉴얼 사용 - 페이지 46
{카테고리_이름} Dell PowerEdge C6105에 대한 매뉴얼 사용을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerEdge C6105 46 페이지. Rack server
Dell PowerEdge C6105에 대해서도 마찬가지입니다: 포트폴리오 매뉴얼 (27 페이지), 기술 매뉴얼 (36 페이지)
>11 00 00
2 Enable and Set VLAN ID :
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x0C
0x01 0x01 0x14 0x02 0x80
3 Disable VLAN ID :
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x0C
0x01 0x01 0x14 0x00 0x00
BMC Version Information
The BMC firmware version can be obtained by using the IPMI - Get Device
ID command.
To get the BMC firmware version:
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x06
0x01
>20 01 01 16 02 bf 4c 1c 00 47 32 11 76 00 00 Version 1.16
BIOS Firmware Information
The BIOS firmware version can be obtained by using the IPMI - Get Device
ID command.
To get the BIOS firmware version:
> ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x30
0x1e
> 53 32 47 5F 33 41 31 35 00 00 Present with ASCII Code : S2G_3A15
46
VLAN is disabled/VLAN ID is zero.