Juga untuk Dell PowerVault MD3200 Series: Manual Pembaruan (32 halaman), Petunjuk Pemasangan Rak (2 halaman), Matriks Dukungan (12 halaman), Panduan Penyebaran (38 halaman), Pembaruan Informasi (1 halaman), Matriks Dukungan (17 halaman), Buku Panduan Teknis (40 halaman), Buku Putih (22 halaman), Panduan Penyebaran (38 halaman), Panduan Penyebaran (38 halaman)

Dell PowerVault MD3200 Series Panduan Instalasi

Managing SMI-S Provider

Starting and Stopping the OpenPegasus CIM
Server

For Windows

To start or stop the OpenPegasus CIM server:
Open the Services window and locate the cimserver service. Right-click
cimserver service and select start or stop.
Or
In the command prompt:
To start the service, type: net start cimserver
To stop the service, type: net stop cimserver

For Linux

To start or stop the OpenPegasus CIM server, on a terminal window:
To start the service, type: cimserver
To stop the service, type: cimserver -s
Adding or Removing a Storage Array From SMI-S
Provider
At installation, you are prompted to enter the IP addresses into a file. After
this initial setup, the SMI-enabled client must use the SMI-S Provider proxy
server system management profile to add or remove devices.
NOTE:
When a storage array is added, an IP address of only one of the
management ports of the storage array must be supplied (and not both
management ports). Entering the IP addresses for both management ports of a
single storage array causes unpredictable behavior of the SMI-S Provider.