Juga untuk Dell PowerVault MD3060e Series: Manual Perangkat Keras dan Perangkat Lunak (25 halaman), Panduan Instalasi (11 halaman), Panduan Memulai (10 halaman), Pembaruan Informasi (8 halaman), Petunjuk Pemasangan Rak (2 halaman), Menyiapkan (2 halaman), Panduan Penyebaran (24 halaman), Panduan Administrator (35 halaman), Panduan Memulai (10 halaman), Panduan Penyebaran (24 halaman), Panduan Pemilik (40 halaman), Menyiapkan (2 halaman)

Dell PowerVault MD3060e Series Panduan Administrator
Parameter
-event

Update commands

Update drive firmware

Description
This command updates the firmware version of the specified drives by using the provided firmware file.
This command also verifies the integrity of the firmware file before applying the firmware.
Command syntax
secli (update drive | updatedrive | ud) (-a=<(SAS WWID | AdapterIndex)> [-
enc=<(WWN | EnclIndex)> [-w=<DrawerIndex>]] [-d=<(WWN | EnclosureSlotIndex |
DrawerSlotIndex | Serial Number | Drive OS Path)>] (-file=<FW.FilePath> [-
force] | -directory=<FW.DirectoryPath>) [-show] [-multi]
w=<DrawerIndex>] [-d=<(WWN | EnclosureSlotIndex | DrawerSlotIndex | Serial
Number | Drive OS Path)>] (-file=<FW.FilePath>[-force] | -
directory=<FW.DirectoryPath>) [-show] [-multi]
| DrawerSlotIndex | Serial Number | Drive OS Path)> (-file=<FW.FilePath>[-
force] | -directory=<FW.DirectoryPath>) [-show] [-multi]
Parameters
Table 24. Update drive firmware
Parameter
-a
-d
-enc
-w
-file
34
Description
Display logs of the given event severity type. This could be either of the
following: INFO, CRITICAL, ERROR, WARN. Logs are printed irrespective of the
severity level, if this argument is not provided.
| -enc=<WWN> [-
| -d=<(WWN | EnclosureSlotIndex
| [-h])
Description
Specify the adapter used for the command. This is
either SAS WWID or AdapterIndex.
Specify the HDD used for the command. This can
be any of the following:
WWN—Can be used anytime.
Serial Number—Can be used anytime.
Drive OS path—Can be used anytime.
Enclosure Slot Index—Use if drawer argument
is not used for the command.
Drawer Slot Index (Index of the drive in the
specific drawer)— Use if drawer argument is
used for the command.
Specify the enclosure used for the command. This
is either WWN or EnclIndex.
Specify the drawer index used for the command.
Specify the file at the given path used for the
command.