Juga untuk Dell PowerVault MD3260 Series: Manual Perangkat Keras dan Perangkat Lunak (25 halaman), Panduan Instalasi (11 halaman), Panduan Memulai (10 halaman), Pembaruan Informasi (8 halaman), Petunjuk Pemasangan Rak (2 halaman), Menyiapkan (2 halaman), Panduan Penyebaran (26 halaman), Panduan Penyebaran (24 halaman), Panduan Memulai (9 halaman)

Dell PowerVault MD3260 Series Panduan Konfigurasi
Figure 7. Four Host Servers With Single-Port HBAs Connected to a Dual-Controller (Duplex) Storage Array Using Cluster Cabling
Figure 7 shows a four-cluster node connected to two RAID controller modules. Since each cluster node has redundant
paths, loss of a single path still allows access to the storage array through the alternate path.

SAN-Attached Cabling

SAN-attached cabling configurations provide the highest level of redundancy and alternate-path connectivity between
the host server and storage array. A SAN configuration using a Fibre Channel compatible switch fabric allows you to
establish multiple redundant paths to data on the storage array.
NOTE: A SAN configuration using a supported Fibre Channel switch hardware is required if the Remote Replication
premium feature is activated on the storage array. Remote Replication is not supported in a direct-attached
configuration. For specific cabling requirements for Remote Replication, see Remote Replication Cabling Example.
SAN-Attached Cabling Example
The following figure shows a three-server, mixed HBA cabling configuration that uses two separate switch fabrics to
establish multiple paths to the storage array. Port-to-port connections in each switch fabric/zone are detailed in the text
boxes.
14