Dell PS4110 Panduan Pemilik Perangkat Keras - Halaman 37

Jelajahi secara online atau unduh pdf Panduan Pemilik Perangkat Keras untuk Penyimpanan Dell PS4110. Dell PS4110 48 halaman. Storage arrays
Juga untuk Dell PS4110: Panduan Pengguna (20 halaman), Manual Perangkat Keras (50 halaman), Ikhtisar (7 halaman), Instalasi (2 halaman)

Dell PS4110 Panduan Pemilik Perangkat Keras

4 Maintaining Power Supply and Cooling Modules

The array can support two hot-swappable power supply and cooling modules.
The array can operate only temporarily with one module, but both modules must be present for long-term cooling
of the array.

About Power Supplies

The PS Series array receives power from two power supplies (PSUs).
Each PSU has a 700W power supply. Each power supply has two cooling fans.
The fans that keep the array cool are integrated into the power supply modules and cannot be replaced
separately. If a fan fails, you must replace the entire power supply module.

Identifying Power Supply Failures

You can identify a power supply and cooling module failure by any or all of the following:
LEDs on the power supply and cooling modules.
Messages on the console, in the event log, or in the Group Manager GUI Alarms panel.
Group Manager GUI and CLI output. The GUI Member Enclosure window or the CLI
command shows a power supply and cooling module failure.
show enclosure
When viewing the rear of the array, power supply 0 is on the right, and power supply 1 is on the left.
Note:
Power Supply LEDs
The power supplies and cooling modules have LEDs that indicate their status.
Figure 23
illustrates the power supply LEDs.
See "Power Supply LEDs" on page 33
Table 7
describes these LEDs.
for details.
member select
33