Dell Networking S5000 Panduan Konfigurasi - Halaman 8
Jelajahi secara online atau unduh pdf Panduan Konfigurasi untuk Beralih Dell Networking S5000. Dell Networking S5000 17 halaman. Data center switch
Juga untuk Dell Networking S5000: Panduan Instalasi (50 halaman), Panduan Konfigurasi (12 halaman), Panduan Memulai (37 halaman)
FTOS(conf)#no dcb enable
FTOS(conf)#exit
FTOS#copy running-config startup-config
2.4
Configure out of band (OOB) management port
FTOS>enable
FTOS>#config
FTOS(conf)#interface Managementethernet 0/0
FTOS(conf-if-ma-0/0)#no shutdown
FTOS(conf-if-ma-0/0)#ip address ipaddress mask
FTOS(conf-if-ma-0/0)#exit
2.5
Configure route for OOB management port (optional)
FTOS (conf)#management route X.Y.Z.0 /24 A.B.C.1
Note: X.Y.Z.0 is the network your management system is connecting from and A.B.C.1 is the gateway for
the switch. If your management system is on the same subnet as the switch, the previous step may be
omitted. The example above assumes a class C subnet mask.
2.6
Configure login credentials
FTOS(conf)#username admin password yourpassword privilege 15
FTOS(conf)#enable password yourpassword
2.7
Enable switch ports
Option 1: You can enable ports individually by entering the port number
FTOS(conf)#interface tengigabitethernet 0/0
FTOS(conf-if-te-0/0)#switchport
FTOS(conf-if-te-0/0)#no shutdown
FTOS(conf-if-te-0/0)#exit
Option 2: You can enable multiple ports at once using the "range" parameter
8
SCG1007
Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs