14. Advanced functions
Through the 8-position dip switch, it is possible to personalize further the automation functions. As standard the control panel leaves the factory
with all the main functions already set, however, it is always possible to modify them by following the table:
Dip No.
1
modality of functioning
2
learning of the courses
3
4
5
electrical lock + water hammer
6
7
8
14.1 Modality of functioning
Setting the dip n° 1 on ON and the dip n° 2 on OFF, the manual functioning is enabled. This functioning allows the displacement of the wing with
the red and blue keys present on the card (see paragraph 4)
14.2 Strokes learning
Setting the dip n° 1 on OFF and the dip n° 2 on ON, t he learning of the strokes is enabled. This functioning allows to learn the courses and the
phase shift of the wings (see paragraph 6).
Setting the dip n° 1 on ON and the dip n° 2 on ON, the pedestrian opening is enabled. This functioning allows to learn the opening of the first wing
when the pedestrian opening key is pressed (see paragraph 11).
14.3 Pre – flashing
Setting the dip nr.3 on ON the pre – flashing is enabled. This function means that before any movement there will be a brief flashing in order to
indicate the movement is about to begin. Remember to turn the control unit off and then on again after modifying the dip switch's configuration.
14.4 Condominium function
Every command sent via radio or with the step by step buttons and/or pedestrian buttons will only open the door. Reclosure is entrusted to the
automatic reclosure function, which must be activated since all closure command are ignored. In case the condominium function is active and the
automatic reclosure is deactivated by means of the respective regulation trimmer (turned completely in clockwise sense), the control panel puts
itself in state of signalled alarm, with door closed, through fast blinkings of the flashing light. Set dip n° 4 on ON to activate the condominium
function.
14.5 Water hammer and electrical lock
If the automation is equipped with an electro lock it is advisable that, with the gate closed, the motor acts in closure for a short time before starting
the opening phase. This functions allows you to un-lock the electro lock even in harsh weather conditions (e.g. ice). In order to activate the water
hammer set dip no. 5 to ON.
14.6 Photocells check
This control unit is equipped with a function which allows you to carry out a check of the photocells operation before any turning on of the motor. In
this way there is the possibility of increasing the safety of the system in case of photo device damaging (for example output relay stuck) or of an
unwanted short – circuit on the photocell input. In case of breakdown, the control panel will signal it through a single flashing when a key is
pressed and no movement will take place. This check is carried out after the control panel has received an order to move, but therefore powering
the motor. Set dip n° 6 on ON to activate the photo cell check.
14.7 Clock function
Setting the dip n° 7 on ON the timing function is a ctivated. The pedestrian input becomes timing input where it is possible to connect a timer for the
programming opening of the gate. The contact is interpreted as request of opening and of permanence on the opening state until the contact
remains closed. When the contact opens, the gate automatically closes.
14.8 Wings number setting
The control unit AS24 can work with 1 or 2 wing gates. This setting is carried out putting the dip n° 8 on OFF if you want a 2 wing functioning and
on ON if you want a single wing functioning. This setting MUST be carried out before the learning of the strokes.
6-1622372
rev.5 04/02/2016
function
Pre-flashing
Condominium function
Photocell check
time set
number of wings
ITA
Dip OFF
Automatic
disabled
Not active
Not active
Not active
disabled
Not active
2 wings functioning
ENG
FRA
ESP
DEU
POR
Dip ON
Manual
enabled
Active
Active
Active
enabled
Active
1 wing functioning