4.3 Programming menu A (key P1)- List of parameters
The following table lists the entries of menu A and reports a short description of the parameters that can be adjusted; refer to paragraph ADVANCED
FUNCTIONS for more details
MENÙ A
AutoReclosingTim
PhotoAutoReclose
Brake
Dead Man
Condominium
Photo Inv
Photo Test
Edge Inv
Edge Test
Preblink
Area Light
Lighting time
Display
OK
HH:MM:SS: Timed closure of the gate (only from total or pedestrian opening)
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
HH:MM:SS
OFF:
Immediate closing after the intervention of the photocell (only from total or
pedestrian opening)
OFF
disabled
ON
the gate closes 3 seconds after the contact between photocell has
restored
Electronic brake operation (for motors with high inertia).
disable
OFF
1
Electonic brake.
2
activation of the contact for external brake, active with motor switched off.
3
activation of the contact for external brake, active with motor switched on.
"Dead Man" mode. The motor moves only by means of a permanent
command
disabled
OFF
ON
enabled (WARNING: automatic motions are disabled)
Condominium function. The commands S.S. and PED allow only the
OFF
opening of the gate disabled
ON
enabled (WARNING: enable the "Automatic Re-Closure" in order to close)
Photocell intervention modality
OFF
the gate stays still until the obstacle is removed, and then opens
completely
ON
the gate opens completely (this function does not apply in opening)
Functional test of the photocell; it is executed before the gate moves
OFF
disabled
ON
test activated (WARNING: supply the photocell with power as shown in
the scheme)
Modality of operation of the safety edge (sensible edge)
the gate stops
OFF
ON
the gate opens completely (this function does not apply in opening)
Functional test of the safety edge; it is executed before the gate moves
OFF
disabled
test activated (WARNING: supply the safety edge with power as specified
ON
in the chap. 2.8)
Short flash before the motion of the gate
OFF
disabled
enabled
ON
Modality of functioning of the auxiliary output for lighting
courtesy light
OFF
ON
zone light (lit-off only when the gate is completely closed)
Auxiliary light's switching-off delay for lighting
OFF
Auxiliary light's output disabled
switching-off delay - auxiliary light's output enabled