Allmatic INVERTER COMPACT Instruksi - Halaman 13

Jelajahi secara online atau unduh pdf Instruksi untuk Pembuka Pintu Garasi Allmatic INVERTER COMPACT. Allmatic INVERTER COMPACT 20 halaman.

High Speed CL
Low Speed CL
High Torque OP
Low Torque OP
High Torque CL
Low Torque CL
EXIT
4.5 Programming menu C (key P3) - List of parameters
The following table lists the entries of menu A and reports a short description of the parameters that can be adjusted; refer to paragraphs dedicated to
each function for more information
MENÙ C Display
Language
Backlight
Reset
EXIT
OK
NNNHz
OK
NNNHz
OK
NNN%
OK
NNN%
OK
NNN%
OK
NNN%
OK
OK
OFF
OK
OK
OK
Regulation of the normal speed of the gate during the closing phase
speed expressed in Hz (frequency of the wave supplied to the motor)
Regulation of the speed of the gate during the closing phase when approaching
the end of the run
speed expressed in Hz (frequency of the wave supplied to the motor)
Torque supplied to the motor during the opening phase at normal speed
percentage of torque supplied to the motor (000%...100%)
Torque supplied to the motor during the opening phase when approaching the
end of the run
NNN: percentage of torque supplied to the motor (000%...100%)
Torque supplied to the motor during the closing phase at normal speed
percentage of torque supplied to the motor(000%...100%).
Torque supplied to the motor during the closing phase when approaching the
end of the run
percentage of torque supplied to the motor (000%...100%).
Select the language (where applicable)
Backlighting of the display
the light of the display is disabled
ON
the light of the display is enabled and its automatic switching-off is timed
(Energy saving)
Total reset of factory settings of the control board.
WARNING: all programming operations and the setting of the control board must
be repeated after this operation
13 / 20