Miele Imperial DIF 976 EX Panduan Pengoperasian dan Instalasi - Halaman 20

Jelajahi secara online atau unduh pdf Panduan Pengoperasian dan Instalasi untuk Kap Ventilasi Miele Imperial DIF 976 EX. Miele Imperial DIF 976 EX 32 halaman.

Miele Imperial DIF 976 EX Panduan Pengoperasian dan Instalasi
If exhaust ducting with a diameter of
less than 150 mm or flat ducting were
to be used the noise level of the cooker
hood would increase and extraction
would be less efficient.
– If the cooker hood is to be con-
nected to an external fan, first make
the required hole
must be 65 x 30 mm in order to feed
the six pole connecting plug
through. Then feed the connecting
cable to the external fan.
If required the extension cable sup-
plied with the external fan should be
used.
– Drill four ø 10 mm holes in the ceil-
ing, and plug with S10 plugs.
The fixings supplied are for use in
concrete ceilings. For other types of
ceiling alternative suitable fixings
will be required.
20
d
in the ceiling. It
– Attach the ventilation ducting to the
exhaust stub on the ceiling plate and
secure using the hose clip.
– Insert the two spring retainers from
below into the slots provided in the
ceiling plate.