HP 234664-002 - ProLiant - ML330T02 Panduan Pelaksanaan - Halaman 16

Jelajahi secara online atau unduh pdf Panduan Pelaksanaan untuk Desktop HP 234664-002 - ProLiant - ML330T02. HP 234664-002 - ProLiant - ML330T02 26 halaman. Visualization and acceleration in hp proliant servers
Juga untuk HP 234664-002 - ProLiant - ML330T02: Pertanyaan yang Sering Diajukan (4 halaman), Panduan Pelaksanaan (35 halaman), Buku Putih Teknis (12 halaman), Pembaruan Firmware (9 halaman), Ikhtisar (20 halaman), Panduan Pengenalan (22 halaman), Panduan Pemecahan Masalah (18 halaman), Panduan Pelaksanaan (11 halaman), Panduan Instalasi (2 halaman), Panduan Konfigurasi (2 halaman), Panduan Pengenalan (19 halaman), Manual Pembaruan (9 halaman), Manual Pembaruan (16 halaman), Panduan Pengenalan (10 halaman), Panduan Petunjuk Instalasi (15 halaman), Ringkasan Teknologi (9 halaman)

HP 234664-002 - ProLiant - ML330T02 Panduan Pelaksanaan

IPMI and WS-Management for the HP ProLiant 100 Series servers

The HP ProLiant 100 Series servers listed in Table 6 contain a Baseboard Management Controller
(BMC).
Table 6. Supported ProLiant 100 Series Servers with Baseboard Management Controller
Server platform
ProLiant DL140 G2
ProLiant DL140 G3
ProLiant DL145 G2
ProLiant ML110 G3
ProLiant ML110 G4
HP IPMI Provider for HP BladeSystem servers and ProLiant 300 and 500
Series servers
For HP BladeSystem servers and ProLiant 300 and 500 Series servers that do not contain IPMI
hardware, the IPMI Provider is required for IPMI functionality. The HP IPMI Provider emulates the
Microsoft IPMI Provider by collecting IPMI data from the HP System Management Controller Driver
and making it available through the "root\hardware" WMI namespace.
ProLiant 300 and 500 Series G4 servers and older require the IPMI Provider that is included in the
Windows Server 2008 PSP 8.00.

Failover Clustering

Failover clustering is available in the Enterprise and Datacenter editions of Windows Server 2008.
Installed through the Add Features menu in Server Manager, failover clustering allows multiple servers
to work together to increase the availability of applications and services. Windows Server 2008
failover clustering does not support parallel SCSI-based storage solutions. Only SCSI-3 command-
capable storage functions with Windows Server 2008 failover clustering.
HP delivers intelligent fault resilience with its High Availability Clustering product solutions and kits
built on industry standard ProLiant servers running Windows Server 2008 and Smart Array Cluster
Storage, or StorageWorks platforms integrated with HP management tools.
Administrators should review the Microsoft documentation for failover clustering at:
http://technet2.microsoft.com/windowsserver2008/en/library/3ce5c4f2-558d-4daf-ae86-
54c9734a53bf1033.mspx?mfr=true.
NOTE
Storage that was compatible with server clusters in Windows
Server 2003 might not be compatible with failover clusters in
Windows Server 2008.
ROM family
DL140G2
DL140G3
DL145G2
ML110G3
ML110G4
Minimum ROM date
03/31/06
06/18/06
03/23/06
02/13/06
06/05/06
16