Gas connection
Gas connection
Connection to the gas supply, or
conversion from use on one type of
gas to another should only be
undertaken by an approved Corgi
registered fitter, who is responsible
for correct functioning of the ap-
pliance when installed.
The gas hob is suitable for natural gas
and LPG, and is supplied as standard
for connection to natural gas.
Check with your local Gas Supplier
for details about the type of gas and
calorific value and compare this in-
formation with the type of gas
quoted on the data plate.
For LPG consult your Miele-Dealer
or the Service Department for the
correct gas jet kit.
Instructions for conversion to alterna-
tive forms of gas can be found in the
following Section.
The gas connection must be in-
stalled so that it can be connected
either from inside or outside the kit-
chen unit and the stop-valve must
be easily accessible and visible, by
opening one of the furniture doors,
if necessary.
An appropriate rigid or flexible connec-
tion can be used.
The gas connection must be in accord-
ance with local and national regulations
and should be tested for possible leakage.
20
The appliance may only be connected
by a registered gas fitter (eg Corgi in
the UK), who is responsible for correct
functioning of the appliance when in-
stalled.
When the gas hob has been in-
stalled, it is essential to check that
neither the gas pipe nor the mains
cable are in contact with hot parts
of the appliance, otherwise tempera-
ture damage to the pipe and the
cable could occur.
Nominal rating for all types of gas at
the high setting:
Gas type
Burner
Natural gas
Liquid gas
Nominal rating for all types of gas at
the low setting:
Gas type
Burner
Natural gas
Liquid gas
Contact your local gas supplier if the
natural gas connection pressure is less
than 18 mbar or higher than 25 mbar.
kW
5.75
5.40
kW
0.20
0.20