5-2.

Connection Diagram

Turn Off wire feeder and welding
power source. Stop engine on weld-
ing generator.
Do not move or operate equipment
where it could tip.
Use only with CC/CV DC power
sources.
1 Welding Power Source
2 Gas Hose
3 Weld Cable To Feeder
4 Weld Cable To Workpiece
5-3.

ArcReach Applications

To take advantage of the ArcReach features, the ArcReach wire feeder must be used with an ArcReach Control, or an ArcReach compati-
ble welding power source. The ArcReach wire feeder may also be used as a standard feeder on any Non-ArcReach power source.
This wire feeder has the ability to associate with an ArcReach compatible welding power source at power up, or when wire feeder is trig-
gered. For either method, the welding power source must be in an Output On mode. See instructions in the welding power source Owner's
Manual.
This wire feeder has the Cable Length Compensation feature, see Section 6-3 for details.
5-4.
Associating Wire Feeder To ArcReach Compatible Power Source Or ArcReach
Control
Associating wire feeder to an ArcReach compatible welding power source at power up
The welding power source must be in an Output On mode. See instructions in the welding power source Owner's Manual.
On wire feeder, set CC/CV switch to CV mode. The feeder will not associate with another piece of equipment if the feeder is set to CC
mode.
If associating to a Power Source with the Cable Length Compensation feature, see Section 6-3 for details.
1 Turn on the welding power source and wire feeder.
2 Decimal points on feeder voltmeter will blink.
3 When decimal points stop blinking and a voltage is displayed, the feeder and power source are associated. The association process may
take several seconds to complete.
OM-278792 Page 16
Complete Parts List is available at www.MillerWelds.com
1
2
3
4
5
Weld cable and work cable connections to
power source (DCEN/DCEP) are dependant
on wire type.
Since feeder is not polarity sensitive,
there is no need for an electrode polar-
ity switch.
5 Workpiece
6 Voltage Sensing Clamp
Connect
voltage
sensing
workpiece.
10
9
Ref. 278805-A
7
6
7 Gun
8 Gun Trigger Receptacle
9 Wire Feeder
10 Gas Cylinder
Use of shielding gas is dependant on wire
type.
Shielding gas pressure not to exceed
clamp
to
100 psi (689 kPa).