Miller ArcReach SuitCase 12 CE Руководство пользователя - Страница 22
Просмотреть онлайн или скачать pdf Руководство пользователя для Сварочная система Miller ArcReach SuitCase 12 CE. Miller ArcReach SuitCase 12 CE 48 страниц.
5-2.
Connection Diagram
Turn Off wire feeder and welding
power source. Stop engine on weld-
ing generator.
Do not move or operate equipment
where it could tip.
Use only with CC/CV DC power
sources.
1 Welding Power Source
2 Gas Hose
3 Weld Cable To Feeder
4 Weld Cable To Workpiece
5-3.
ArcReach Applications
�
To take advantage of the ArcReach features, the ArcReach wire feeder must be used with an ArcReach Control, or an ArcReach compati-
ble welding power source. The ArcReach wire feeder may also be used as a standard feeder on any Non-ArcReach power source.
�
This wire feeder has the ability to associate with an ArcReach compatible welding power source at power up, or when wire feeder is trig-
gered. For either method, the welding power source must be in an Output On mode. See instructions in the welding power source Owner's
Manual.
�
This wire feeder has the Cable Length Compensation feature, see Section 6-3 for details.
5-4.
Associating Wire Feeder To ArcReach Compatible Power Source Or ArcReach
Control
Associating wire feeder to an ArcReach compatible welding power source at power up
�
The welding power source must be in an Output On mode. See instructions in the welding power source Owner's Manual.
�
On wire feeder, set CC/CV switch to CV mode. The feeder will not associate with another piece of equipment if the feeder is set to CC
mode.
�
If associating to a Power Source with the Cable Length Compensation feature, see Section 6-3 for details.
1 Turn on the welding power source and wire feeder.
2 Decimal points on feeder voltmeter will blink.
3 When decimal points stop blinking and a voltage is displayed, the feeder and power source are associated. The association process may
take several seconds to complete.
OM-278792 Page 16
�
Complete Parts List is available at www.MillerWelds.com
1
2
3
4
5
Weld cable and work cable connections to
power source (DCEN/DCEP) are dependant
on wire type.
�
Since feeder is not polarity sensitive,
there is no need for an electrode polar-
ity switch.
5 Workpiece
6 Voltage Sensing Clamp
Connect
voltage
sensing
workpiece.
10
9
Ref. 278805-A
7
6
7 Gun
8 Gun Trigger Receptacle
9 Wire Feeder
10 Gas Cylinder
Use of shielding gas is dependant on wire
type.
�
Shielding gas pressure not to exceed
clamp
to
100 psi (689 kPa).
8