3-10. Remote 7 Receptacle Information (TIG And Stick Only)

7-Pin Remote Receptacle
.
This remote receptacle cannot be used with a standard Miller remote control. A customer supplied remote control is required to use the remote
receptacle.
Some signals can be enabled when TIG or Stick welding. Contact Factory Authorized Service Agent for confirmation.

3-11. Circuit Breakers

Socket
1
+10 volts DC supply voltage to remote
2
GND Remote control circuit common
3
IREF 0 to 10 current control signal
4
Not used.
5
UP 0V/10V digital signal
6
Not used.
7
TYPE 0V/10V digital signal
1
2
Socket Information
Circuit breakers with numbers 7
and 10 are placed on the rear panel
of the welder as shown.
1
Circuit Breaker 7
Protects the auxiliary 115 volt AC
output from overload. The 115 volt
AC output powers the water cooling
unit inside the power source.
2
Circuit Breaker 10
Protects the auxiliary 24 volt AC
output from overload. The 24 volt
AC output powers the wire feeder
inside the power source.
Ref. 956142645-4-5
OM-244 243 Page 13