Miller XMS 403 Owner's Manual - Page 17

Browse online or download pdf Owner's Manual for Welding System Miller XMS 403. Miller XMS 403 44 pages. 400 volts ce arc welding power source

Miller XMS 403 Owner's Manual

3-10. Remote 7 Receptacle Information (TIG And Stick Only)

7-Pin Remote Receptacle
.
This remote receptacle cannot be used with a standard Miller remote control. A customer supplied remote control is required to use the remote
receptacle.
Some signals can be enabled when TIG or Stick welding. Contact Factory Authorized Service Agent for confirmation.

3-11. Circuit Breakers

Socket
1
+10 volts DC supply voltage to remote
2
GND Remote control circuit common
3
IREF 0 to 10 current control signal
4
Not used.
5
UP 0V/10V digital signal
6
Not used.
7
TYPE 0V/10V digital signal
1
2
Socket Information
Circuit breakers with numbers 7
and 10 are placed on the rear panel
of the welder as shown.
1
Circuit Breaker 7
Protects the auxiliary 115 volt AC
output from overload. The 115 volt
AC output powers the water cooling
unit inside the power source.
2
Circuit Breaker 10
Protects the auxiliary 24 volt AC
output from overload. The 24 volt
AC output powers the wire feeder
inside the power source.
Ref. 956142645-4-5
OM-244 243 Page 13