Congratulations on the product you have chosen. The injection arm is made of 3B SKINlike
extremely durable. The injection arm can be used to train intravenous injections, punctures of the peripheral
veins [basilic v., cephalic v., median cubital v., hand (dorsal venous network)].
Accessories:
• 1 injection arm
• 1 infusion bottle
• 1 suspension net
• 1 rubber cork
• 1 infusion system with air filter
• 1 stand (with 2 height-adjustable hanging devices)
• 1 bottle of artificial blood
• 1 cup
• 1 disposable syringe
• 2 injection cannulas (recommended cannula size: 20 and 21 gauge)
• 2 tubing systems with (white) sealing caps as replacement parts
• 4 (white) sealing caps as replacement parts
• 1 can of talcum powder
Mounting the injection arm
• Attach the upper hanging device at the red mark on the stand and the lower one at a height of approx. 10 cm.
• Hang the injection arm onto the lower hanging device using the ring screw.
• Fill water into the infusion bottle and add a few drops of the artificial blood.
• Put the rubber cork on the infusion bottle.
• Pull the suspension net over the infusion bottle.
• Close the flow control of the infusion system (Fig. 1).
• Prick the tip of the infusion system as far as possible through the rubber cork (Fig. 2).
• Hang the infusion bottle into the upper hanging device of the stand.
• Fill the drip chamber of the infusion system by pressing together the chamber walls and open the air
filter (Fig. 3).
• First remove the sealing cap of the infusion tube and then the sealing cap of the short tube on the injection
arm and connect these (Fig. 4).
• Remove the sealing cap of the long tube on the injection arm and hang the tube in the cup.
• Now open the flow control of the infusion system and close the flow control again as soon as the artificial
blood reaches the cup. Place the sealing cap on the long tube (Fig. 5).
• You can now begin puncturing the peripheral veins (Fig. 6).
• In case of frequent puncture procedures please make sure to open the flow control again to allow more
artificial blood to flow in, then close it again.
Rinsing the tubing system
When you do not use the injection arm for a prolonged period of time, it is recommended to rinse the
tubing system so that no dye residues can settle in the system.
• Instead of the artificial blood, please fill water into the infusion bottle.
• Open the flow control, remove the sealing cap of the long tube on the injection arm and hang the tube
in the cup until the water reaches the cup.
• Close the flow control and place the sealing caps on the tubes.
Changing the skin and the tubing system
How to pull off the skin:
• To change the skin of the injection arm, unfasten the ring screw of the injection arm, remove the sealing
caps from the tubes, remove the cover plates, pull the tube through the locating hole and pull the skin
off the core of the arm.