5. RO-101S installation, Сont.
Connection node assembly
Turn the water off at the cold water main.
‰
Open the kitchen faucet to discharge pressure into the water line.
‰
Unscrew the nut from the flexible line cap, leading to the faucet on the cold water main.
‰
ATTENTION! Residual water will be left inside of the flexible JG tube after discharge of water.
When disconnecting the flexible line, please use a 200 ml or similar size container to drain the
water left behind in the tube.
Screw the cap nut off the connection node and on the cold water main thread.
‰
Screw the cap nut off the flexible line, and then on the connection node thread.
‰
Set the shutoff valve on the connection node to the closed position and then make sure that the connection
‰
is completely leak-proof by supplying water to the cold water main.
Connect JG tube (follow the instructions below to correctly connect the JG tubes).
‰
ATTENTION! The sealing O-Ring is located correctly in its place and not damaged during
installation.
AQUAPHOR RO-101S REVERSE OSMOSIS SYSTEM
Shutoff valve set
in closed position
Locking clip
Sealing O-Ring
Cold water main
Figure 5. Connection node installation scheme
Connection
node
9