Installation

IMPORTANT: Before installing the IonGen
System in existing water features, it is
recommended to thoroughly clean the pond of
as much algae and debris as possible. This will maximize
the ions' effectiveness and speed to achieve desired
results. The more algae and debris in the water feature,
the longer it will take the Aquascape IonGen System to
provide noticeable results.
STEP 1
MOUNT THE CONTROL
PANEL
• Mount the IonGen System
Control Panel in the desired
location (Ex. 1); making sure
the power cord reaches
the GFI outlet and the
IonGen Probe cord reaches
the desired location of
the IonGen Probe. A 25'
Extension Cable with Quick-Connects (sold separately) is
available, if needed. The IonGen System Control Panel is
weather-resistant, but in order to maximize the lifespan of
your unit, we suggest mounting the panel above ground in
a location protected from the elements.
STEP 2
INSTALL THE FLOW CHAMBER
• The Flow Chamber for the IonGen System can be
located in several areas within the water feature. The
Flow Chamber is most effective when plumbed directly
into the water feature's recirculating system. The IonGen
Probe can also be installed without the Flow Chamber by
submerging it in a filter, such as in a skimmer or Pondless
Waterfall Vault. Follow the step-by-step installation
instructions for the method you select.
Option A: Install into Recirculating System
• Cut and insert the Flow Chamber into the water feature's
recirculating system (Ex. 2). The Flow Chamber should
be positioned after the water feature's pump, and in a
region of the plumbing line that drains by gravity. This
enables you to easily service the IonGen Probe and allows
for overwintering the Flow Chamber and fittings. It is
recommended to use a pre-filter, such as a skimmer, prior
to the Flow Chamber, in order to remove solids and debris
that may interfere with the IonGen Probe. A small valve
box may be used for easy access during maintenance
(Ex. 3).
4
• Select the fittings needed for the application. The PVC
slip fitting is designed to be used with Schd 40 PVC pipe
rigid or flex and PVC glue. The multi-hose adapter fitting is
designed to be used with kink-free pipe and hose clamps.
Refer to page 3 for adapters and fittings.
• Hand thread the selected
fitting into the Flow Chamber
(Ex. 4).
NOTE: Do not use tools to
Ex. 1
install the fittings into the
Flow Chamber. Fittings need
to be hand-tight only.
• If using a diameter pipe
larger than the smaller hose tails, cut off the hose tails
not being used with a hack saw in order to maximize the
water flow through the plumbing.
• When using the Barbed
Multi-Hose Fitting, use a
metal hose clamp to secure
pipe to fitting (Ex. 5).
• When using PVC, glue pipe
into Slip Fitting using PVC
glue (not included). Follow
the glue manufacturer's
®
directions for proper
plumbing steps (Ex. 6).
• Install the IonGen Probe into the top of Flow Chamber
(Ex. 7).
US (866) 877-6637 |
Ex. 2
CAN (866) 766-3426 | aquascapeinc.com
Ex. 3
Ex. 4
Ex. 5
Ex. 6