HP StorageWorks 2/16 - SAN Switch Catatan Rilis - Halaman 21

Jelajahi secara online atau unduh pdf Catatan Rilis untuk Beralih HP StorageWorks 2/16 - SAN Switch. HP StorageWorks 2/16 - SAN Switch 32 halaman. Fabric os commands
Juga untuk HP StorageWorks 2/16 - SAN Switch: Manual Pembaruan (9 halaman), Panduan Petunjuk Instalasi (20 halaman), Panduan Pengguna (22 halaman), Catatan Rilis Firmware (14 halaman), Catatan Rilis (16 halaman), Panduan Instalasi (14 halaman), Catatan Rilis (10 halaman), Panduan Referensi Cepat (5 halaman)

HP StorageWorks 2/16 - SAN Switch Catatan Rilis

Documentation Updates

Table 4
StorageWorks Diagnostics and System Error Messages Reference Guide.
Table 4: Version 3.1.2 Error Messages Not Previously Available
Severity & Message
Critical
DIAG-BADINT, 1
Critical
DIAG-BUS_TIMEOUT, 1
Critical
DIAG-CAMFLTR, 1

SAN Switch 2/16 Fabric OS 3.1.2 Release Notes

lists error messages that were not available during the release of the HP
Probable Cause
Port received an unexpected
interrupt. This usually indicates an
ASIC failure. This message is
generated by the
centralmemorytest or the
cmitest command, if problems
are found.
ASIC register or ASIC SRAM did not
respond to an ASIC data access.
This usually indicates an ASIC
failure. This message is generated
by the portregtest or the
sramretentiontest command,
if problems are found.
ASIC internal logic failed. This
usually indicates an ASIC failure.
This message is generated by the
filtertest command, if
problems are found.
Documentation Updates
Recommended Action
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL,
replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.