HP XP20000/XP24000 Panduan Konfigurasi - Halaman 26

Jelajahi secara online atau unduh pdf Panduan Konfigurasi untuk Beralih HP XP20000/XP24000. HP XP20000/XP24000 46 halaman. Hp storageworks xp disk array configuration guide: vmware (a5951-96106, september 2010)
Juga untuk HP XP20000/XP24000: Catatan Rilis (13 halaman), Manual Integrasi (29 halaman), Catatan Rilis (4 halaman), Panduan Administrator (50 halaman), Panduan Konfigurasi (42 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (36 halaman), Catatan Rilis (5 halaman), Panduan Konfigurasi (46 halaman), Panduan Referensi (46 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (44 halaman), Panduan Konfigurasi (38 halaman), Panduan Konfigurasi (34 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (30 halaman)

HP XP20000/XP24000 Panduan Konfigurasi
3.
Restart the server.
4.
To see a list of the failover devices and paths, at the server prompt enter:
list failover devices
Example failover device path listing
0x20 [V6E0-A2-D0:0] HP OPEN-3 rev:HP16
Up 0x0D [V6E0-A2-D0:0] HP OPEN-3 rev:HP16
Up
0x1B [V6E0-A3-D0:0] HP OPEN-3 rev:HP16
0x21 [V6E0-A2-D0:2] HP OPEN-3 rev:HP16
Up
0x0F [V6E0-A2-D0:2] HP OPEN-3 rev:HP16
Up
0x1D [V6E0-A3-D0:2] HP OPEN-3 rev:HP16
0x22 [V6E0-A2-D0:4] HP OPEN-3 rev:HP16
Up
0x11 [V6E0-A2-D0:4] HP OPEN-3 rev:HP16
Up
0x1F [V6E0-A3-D0:4] HP OPEN-3 rev:HP16
0x23 [V6E0-A2-D0:1] HP OPEN-3 rev:HP16
Up
0x0E [V6E0-A2-D0:1] HP OPEN-3 rev:HP16
Up
0x1C [V6E0-A3-D0:1] HP OPEN-3 rev:HP16
0x24 [V6E0-A2-D0:1] HP OPEN-3 rev:HP16
Up
0x0E [V6E0-A2-D0:3] HP OPEN-3 rev:HP16
Up
0x1C [V6E0-A3-D0:3] HP OPEN-3 rev:HP16

Helpful Multipath commands

Other useful Multipath commands are described below.
MM Set failover priority <pathid> = <number> </insert>
This command sets the priority level for each path. The ID must be a valid path ID, and the number
must be a decimal integer value in the range 1-4,000,000, with 1 being the highest priority and
4,000,000 being the lowest priority. The default value of 0 (zero) indicates that there is no priority.
The /insert option will move the priorities on all paths that were equal or lower than <number>. For
example, if the paths had priorities of 1,2,3,4, and a new path is assigned a number 2 using the
/insert option, then the paths that were 2, 3, and 4 are moved to 3, 4, and 5, and the new path
assigned priority 2.
MM Set failover state <pathid> = <Up: Down> </setpath>
This command sets the state of the path. The ID must be a valid path ID. If the path is Up, it can be
taken offline, and will not be used to switch to. Another path will be selected. If the path is offline,
the path will be reactivated, if possible, and set to an Up state. The /setpath option will reselect the
highest priority path that is up.
MM Set failover path <pathid>
This command moves the selected path to the one specified by the path ID. The ID must be a valid
path that is up. This does not alter the priorities on the paths, and any reselection of the path may
cause the path to change. A later option will be added to reassign that path to the highest priority.
MM Restore failover path device_id
This command forces the device to reselect the highest priority path that is online. The device_id must
be a valid device ID.
26
Middleware configuration
Priority = 0 selected
Priority = 0
Priority = 0 selected
Priority = 0
Priority = 0 selected
Priority = 0
Priority = 0 selected
Priority = 0
Priority = 0 selected
Priority = 0