Juga untuk HP XP20000/XP24000: Catatan Rilis (13 halaman), Manual Integrasi (29 halaman), Catatan Rilis (4 halaman), Panduan Administrator (50 halaman), Panduan Konfigurasi (42 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (36 halaman), Catatan Rilis (5 halaman), Panduan Konfigurasi (46 halaman), Panduan Konfigurasi (46 halaman), Panduan Referensi (46 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (38 halaman), Panduan Konfigurasi (34 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (30 halaman)

HP XP20000/XP24000 Panduan Konfigurasi

Configuring disk devices

Configure the disks in the disk array using the same procedure for configuring any new disk on the
host. This includes the following procedures:
1.

Creating the disk partitions

2.
Assigning the new devices to volumes
3.
Mounting the new volumes
4.
Verifying client operations
Creating scripts to configure all devices at once can save you considerable time.
Creating the disk partitions
Before you create the disk partitions, consult the Novell documentation for confirmation about the
type of partition that is available with your operating system version.
NetWare 5.x
1.
At the server console enter "LOAD NWCONFIG" to load the Configuration Options module.
2.
On the Configuration Options screen, click Standard disk options and press Enter to access the
NetWare disk options.
3.
On the Available Disk Options screen, select Modify disk partitions and Hot Fix and press Enter.
4.
The Available Disk Drives screen lists the devices by device number. Record the device numbers.
On the Available Disk Drives screen, select the device to partition, and then press Enter.
5.
If the partition table has already been initialized, skip this step. If the partition table has not been
initialized, the partition table message is displayed. Press Enter to confirm the message. When
the Initialize the partition table? message appears, select Yes and press Enter to initialize the
partition table.
6.
On the Disk Partition Options screen, select Create NetWare disk partition, and press Enter.
7.
You are now prompted to create the partition either automatically or manually. Select the desired
option, and press Enter.
If you select automatic partitioning, NetWare will create the disk partition and hot fix area using
the available disk space (the hot fix area will be approximately two percent of the partition size).
If you select manual partitioning, enter a partition size and hot fix area.
8.
On the Disk Partition Information screen, verify (or enter) the partition size and hot fix data area
size, and press F10 to save the changes. The Disk Partition Options screen appears.
9.
Select Create NetWare disk partition again, and press Enter.
10.
When the Create NetWare Partition? message appears, click Yes and press Enter to create the
specified disk partition on the selected device.
11.
Press Esc until you are returned to the Available Devices screen. Repeat
the disk partition on each new OPEN-x and LUSE device.
12.
When you are finished creating disk partitions, return to the Available Disk Options screen, click
Return to previous menu and press Enter.
16
Installing and configuring Novell NetWare for the XP family of disk arrays
Step 4–Step 10
to create