aquatherm AT800 Panduan Instalasi - Halaman 7
Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Pemanas Kolam Renang aquatherm AT800. aquatherm AT800 16 halaman. Swimming pool & spa heat pumps
“black cabinet” with analog controls series only
Juga untuk aquatherm AT800: Panduan Operasional Pemilik (12 halaman), Panduan Instalasi (8 halaman)
Plumbing & Water Connections with Solar
Plumbing for a system where a
solar pool heater is installed. It is
strongly advised that an auto-
matic solar control device be
used when used with the heat
pump.
The heat pump and solar can be
operated together. The heat
pump will share the heating load
with the solar. If there is no heat
coming from the solar panels, the
solar control device will turn off
the solar by rotating the motor
valve, otherwise it should be
turned off manually. The heat
pump will then maintain the
pool/spa temperature.
To use the heat pump as a backup
to the solar, set the heat pump
thermostat 2 to 4 degrees below
the solar's target temperature set-
ting. Therefore, if the solar is not
maintaining water temperature,
the heat pump will come on to
assist the solar. Some thermostat
fine tuning may be required by
the user.
Plumbing & Water Connections for Above or Below Water Level
If you install the heat pump above or below the pool or spa water level by more than 3 feet, the internal
water pressure switch may be effected by the static pressure of the pool water. In some cases it may
be necessary to install a water FLOW switch. The water flow switch is not effected by changes in
water pressure but only water movement. We suggest installing the Grid Brand Model 20 or 25, external
flow switch and disabling the internal water pressure switch. Plumb in the flow switch as shown here.
Then run a THREE wire insulated cable from the flow switch into the heater and attach to the existing
water pressure switch leads located behind the large service panel and wire as shown below.
REVIEW PAGE 8 FOR SIMILAR ACCESS TO LARGE ELECTRICAL SERVICE COMPARTMENT BE-
FORE CONTINUING. REVIEW UNIT WIRING DIAGRAM ON PAGE 10 & 11 ALSO !
If the water pump exceeds 1.5 H.P. then
install either of the optional bypasses as
shown on page 5.
NOTE: If the solar is operated on cloudy days, while
raining, at night or at low air temperatures, it may cool
the pool or spa. A automatic solar control will shut the
solar off when there is no solar activity, otherwise it
should be shut off manually during these times.
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
Page 7
2
4
LOAD
6
5
1
3
.1
8