aquatherm AT800 Panduan Instalasi - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Pemanas Kolam Renang aquatherm AT800. aquatherm AT800 16 halaman. Swimming pool & spa heat pumps “black cabinet” with analog controls series only
Juga untuk aquatherm AT800: Panduan Operasional Pemilik (12 halaman), Panduan Instalasi (8 halaman)

Model Number
Coefficient of Performance
Copeland Scroll™ Compressor
Heat Exchanger Condenser
Air Coil Evaporator
Kilowatt Input
Electrical (208/240v/60Hz)
Typical Running Amps
Minimum Circuit Ampacity
Min/Max Breaker Size
Min. Copper Stranded Wire Size
Min/Max Water Flow
Water Plumbing
Refrigerant Charge
Cabinet Construction
Ship Weight
Model Number
BTU Output
Coefficient of Performance
Compressor
Heat Exchanger Condenser
Air Coil Evaporator
Kilowatt Input
Electrical (208/240v/60Hz)
Typical Running Amps
Minimum Circuit Ampacity
Min/Max Breaker Size
Min. Copper Stranded Wire Size
Min/Max Water Flow
Water Plumbing
Refrigerant Charge
Cabinet Construction
Ship Weight
Dimensions
WARNING: THREE PHASE MODELS:
3 Phase Compressor Is Rogation Sensitive! Use Refrigerant Gages!
Do Not Go By Fan Rotation Since It Will Always Be Single Phase!
HEAT PUMPS
a Division of Calorex USA L.L.C.
2213 Andrea Lane Ft. Myers FL 33912
888-297-3826 941-482-0606
www.aquathermheatpumps.com
www.calorexusa.com
Factory Specifications
AT600
BTU Output
108,000*/102,000**
6.0*/4.9**
ZR67 w/ Receiver Tank
Cupronickel Alloy-Water / Copper-Exterior
Oversized: Copper Tube w Lanced Fin
Fan Motor
Air Flow
4000 C.F.M. w/ Cowling Venturi
5.8 Kw/Hour
Single Phase
27.4 Amps
37 Amps
40/50 Amps
#8 A.W.G.or Larger
20/70 GPM, Over 70 G.P.M. or 1.5 H.P. Add External Bypass
2" Full Flow w Internal Automatic Bypass
R22
Corrosion Proof Molded ABS
305 Lbs.
Dimensions
35H x 31W x 34L
AT800
112,000*/104,000**
6.3*/5.3**
Copeland Scroll™ ZR67 w/ Receiver Tank
Cupronickel Alloy-Water / Copper-Exterior
Oversized Mt. Holly Gold™ Polyester Clad
Fan Motor
1/4 H.P. @ 1.6 Amps
Air Flow
4200 C.F.M. with Built In Cowling Venturi
5.5 Kw/Hour
Single & Three Phase
26.1 Amps / (18.5 Amps @ 3 Phase)
37.8 Amps / (25.4 Amps @ 3 Phase)
40/50 Amps / (25/35 Amps @ 3 Phase)
#8 A.W.G. or Larger
20/70 GPM Over 70 G.P.M. or 1.5 H.P. Add External Bypass
2" Full Flow w Internal Automatic Bypass
R22
Corrosion Proof Molded ABS
324 Lbs.
37H x 31W x 36L
Specifications may change without notice.
Page 9
AT400
92,000*/84,000**
6.4*/5.5**
ZR54 w/ Receiver Tank
1/4 H.P. @ 1.6 Amps
4.4 Kw/Hour
Single Phase
20.4 Amps
35 Amps
35/40 Amps
#8 A.W.G.or Larger
R22
279 Lbs.
29H x 31W x 34L
* Optimum output & efficiency typical of Florida conditions. Ratings
outside the scope of P.H.P.M.A. heat pump pool heater certification
program. ** Rated and certified in accordance with A.S.H.R.A.E.
standard 146-1998 and P.H.P.M.A. addendum test procedure.
Pool
Heat
Pump
Manufacturers
Association
© 2001 Aquatherm Heat Pumps
MEMBER
NATIONAL
POOL & SPA
INSTITUTE