If nitrogen removal is needed the system (The BioBarrier
tanks totaling at least three compartments, with exactly two compartments in the second or final tank. The first compartment or
tank provides primary treatment - sedimentation and separation of floatables and solids, and is equipped with an outlet screening
device called SaniTEE
. The second and third compartments must be in the same tank, and the second compartment is where
®
denitrification takes place under anoxic conditions. The third compartment, the aeration/membrane zone, is separated from the
anoxic zone by a baffle wall between the two zones to allow nitrified waste to enter into the anoxic area for denitrification.
NSF Standard 350 Class R
The BioBarrier
system has been tested under NSF Standard 350 Class R (Residential) and is capable of treating residential
®
wastewater for restricted indoor urban water reuse, which is toilet and urinal flushing. The system design requires a holding tank
and plumbing system for reuse water and shall meet all applicable codes; have proper backflow prevention and protection against
cross connections; and is the responsibility of the local designer/installer. When the reuse water is used for toilet and urinal
flushing, additional disinfection should be considered to provide adequate assurance in preventing microorganism growth in the
treated reuse water storage tank and as required by applicable codes.
The reuse tank shall be located after the BioBarrier
water to be dispersed in a locally approved soil dispersal system or released into a sanitary sewer system. A potable water make
up system shall also be available to supply water when treated reuse water is not available. This potable water make up system
shall include a properly designed backflow preventer that meets all applicable codes.
NSF Standard 350 Class R
The BioBarrier® system has been tested under NSF Standard 350 Class R (Residential) and is capable of treating residential
wastewater for unrestricted outdoor urban water reuse, which is acceptable for use in surface and subsurface irrigation, including
irrigation of edible crops without the edible portion being in direct contact with the treated water. A reuse tank may be required if
the irrigation system requires it. The holding tank and plumbing system for reuse water shall meet all applicable codes; have
proper backflow prevention and protection against cross connections; and is the responsibility of the local designer/installer.
Additional disinfection should be considered to provide adequate disinfection to prevent microorganism growth in the treated
reuse water storage tank and as required by applicable codes.
If a reuse tank is required for irrigation, it shall be located after the BioBarrier® system. This tank shall also incorporate an overflow
that allows excess reuse water to be dispersed in a locally approved soil dispersal system or released into a sanitary sewer
system. If a potable water make up system is required for irrigation, it shall include a properly designed backflow preventer that
meets all applicable codes.

INSTALLATION PROCEDURE

Always have all utility lines and equipment marked by a locating service prior to performing any work. Failure to do so
could result in severe bodily injury or death.
Hazards exist in confined spaces such as a septic tank. All confined space precautions must be followed if entering a
tank. Always keep tank openings covered during storage and installation

MATERIALS REQUIRED FOR INSTALLATION

A. Septic tank that meets all applicable requirements and standards.
B.
Recognized, safe lifting mechanism for treatment module (e.g. a tripod).
C. Non-corrosive strut channel or equivalent material that is able to hold down at least 550 pounds [250 kg] of
buoyant force (see step 29).
D. Stainless steel anchor bolts to secure strut channel to tank riser and blower housing to concrete base.
E.
Piping for all air and vent lines. Check the install procedure all specs, and plans to determine what sizes
and types of pipe you may need.
F.
PVC saw
G. Pipe joint lubricant/soap.
H. PVC primer and glue.
I.
Concrete base for blower assembly.
J.
Mounting screws for control panel.
K.
Electrical conduit, fittings and wire for required wiring.
L.
Hammer Drill and concrete bits.
0.5-N, 1.0-N, 1.5-N) consists of a tank with three compartments, or two
®
Restricted Indoor Urban Reuse Water
system. This tank shall also incorporate an overflow that allows excess reuse
®
Unrestricted Outdoor Urban Reuse Water